Global Network Center (Hong Kong)

OVERVIEW

Data Center Provider

IDC Center Data Center

 

Advantages

  • CMI self-owned property with data center purpose built
  • Over 901 million* mobile subscribers
  • Serves as the hub of International Network Exchange, Internet Data Center (IDC) and Global Network Operation Center (GNOC) in one building
  • Direct connect to all the cities in 31 Mainland Provinces , CMI’s Hong Kong Local Ring and major data centers in Hong Kong
  • The landing station for APG, seamlessly connects with 12 Asian countries and regions
  • Closely connect with SJC & SJC2
  • High-standard 9-layers Security Control

*As of June 2018

Features

Location Tseung Kwan O Industrial Estate
Opening November 2014
Capacity >2,530 racks
Total Gross Floor Area ~24,355 m²
Standard Tier Ⅲ+ (Tier Ⅳ ready)
 

Qualifications

  • ISO/IEC 27001:2013 Information Security Management Systems 
  • ISO 9001:2015 Quality Management Systems
  • Uptime Institute Tier Ⅲ - Tier Certification of Design Documents (TCDD)
  • Uptime Institute Tier Ⅲ - Tier Certification of Constructed Facility (TCCF)
  • Leadership in Energy & Environmental Design (LEED) – Gold 
  • Building Environmental Assessment Method (BEAM) Plus Certification 
  • Payment Card Industry – Data Security Standard (PCI-DSS)
logo-hk

 

map-hk

 

 

Data Hall Specification (3/F –5/F)

Floor Height

  • Slab to Slab Height: 6,250 mm
  • Clear Height: 3,600 mm
  • Raised Floor Height: 800 mm

 

Power

  • Power Capacity: 22MVA From Dual Power Substation With Diversity Path
  • 2N Transformer
  • Dual UPS Supplies to Rack
  • Dual PDU with STS per Rack
  • 2N UPS System with 15 Minutes Backup at Full Load
  • N + 1 Diesel Generator with Fuel Storage for 22 Hours Backup at Full Load
  • Fuel Refill Contract with Supplier for Fuel Delivery within 4 Hours

 

Fire Detection and Protection

  • Very Early Smoke Detection Apparatus (VESDA)
  • Smoke Detector and Heat Detector
  • FM200

 

Data Hall

  • ~285 m2 Raised Floor Area per Data Hall
  • Dual Separated and Dedicated Service Corridor

 

Cooling

  • N + 1 Water Cooled Chiller System
  • N + 1 Cooling Tower
  • N + 2 CRAC System
  • Down Flow System with Hot and Cold Aisles
  • Temperature: 22 +/- 2oC
  • Humidity: 50% +/- 10%

 

Connectivity

  • Carrier Neutral
  • Dual TBE and Meet-Me Room
  • Dual Lead-In to Building with Diversity Path
  • Dual Cable Trunking to Data Hall with Diversity Path
  • APG Cable Landing Station
  • Connection to SJC and SJC2 and Local Fiber Ring in Hong Kong

 

ENQUIRE NOW

Please feel free to give us your feedback or to submit an online enquiry.

Your enquiry is sent.

Name *:

Job Titles:

Company:

Contact number:

Captcha:

Image CAPTCHA

Message *:

ENQUIRE NOW

Please feel free to give us your feedback or to submit an online enquiry.

Image CAPTCHA

ENQUIRE NOW

Your enquiry is sent.