OVERVIEW

IDC-Layout

IDC-Singapore

Advantages

  • CMI self-owned property
  • Over 909 million* mobile subscribers
  • Serves as the hub of International Network Exchange and Internet Data Center (IDC) in one building
  • Direct connect to major data centers and CMI Local Rings in Singapore
  • Closely connect with APG, SJC, SJC2 and SMW5 in order to seamlessly connect with Asia-Pacific (APAC), Indian Ocean as well as Europe, the Middle East and Africa (EMEA) countries /regions
  • High-standard 9-layers Security Control

*As of July 2018

Features
Location Tai Seng, Singapore
Opening End of May 2019
Capacity >2,100 racks
Total Gross Floor Area ~17,490 m²
Standard Tier Ⅲ+ (Tier Ⅳ ready)
 

Qualification

(Under Application)

  • ISO/IEC 27001:2013 Information Security Management Systems
  • ISO/IEC 9001:2015 Quality Management Systems
  • Uptime Institute Tier Ⅲ - Tier Certification of Design Documents (TCDD)
  • Uptime Institute Tier Ⅲ - Tier Certification of Constructed Facility (TCCF)
  • Threat, Vulnerability And Risk Assessment (TVRA)
  • BCA Green Mark (Platinum)
  • Payment Card Industry - Data Security Standard (PCI-DSS)
logo
map
 

Data Hall Specification

Floor Height

  • Slab to Slab Height: 5,000 mm
  • Clear Height: 2,600 mm
  • Raised Floor Height: 800 mm

Data Hall

  • Dual Separated and Dedicated Service Corridor

Power

  • Power Capacity: 20MVA From Dual Power Substation With Diversity Path
  • 2N Transformers
  • Dual UPS and PDU Supplies to Each Rack
  • 2N UPS System with 15 Minutes Backup under Full-load
  • N + 1 Diesel Generator with Fuel Storage for 24 Hours Backup under Full-load
  • Fuel Refill Contract with Supplier for Fuel Delivery within 4 Hours

Cooling

  • N + 1 Water Cooled Chiller System
  • N + 1 Cooling Tower
  • N + 1 CRAC System
  • Down Flow System with Hot and Cold Aisles
  • Temperature: 24 oC +/- 2oC
  • Humidity: 50% +/- 20%

Fire Detection and Protection

  • Very Early Smoke Detection Apparatus (VESDA)
  • Smoke Detectors and Heat Detectors
  • Dry Pre-action Fire Suppression System
  • NOVEC 1230 Suppression System

Connectivity

  • Carrier Neutral
  • Dual Meet-Me Room
  • Dual Lead-In to Building with Diversity Path
  • Dual Cable Trunking to Data Hall with Diversity Path
  • Direct Access to APG, SJC, SJC2 and SMW5 Submarine Cables
  • Direct connect to major data centers in Singapore and CMI Singapore local fiber ring

ENQUIRE NOW

Please feel free to give us your feedback or to submit an online enquiry.

Your enquiry is sent.

Name *:

Job Titles:

Company:

Contact number:

Captcha:

Image CAPTCHA

Message *:

ENQUIRE NOW

Please feel free to give us your feedback or to submit an online enquiry.

Image CAPTCHA

ENQUIRE NOW

Your enquiry is sent.